Tracking cells with omnidirectional visible laser particles

Credit: Shui-Jing Tang, Paul H. Dannenberg, Andreas C. Liapis, Nicola Martino, Yue Zhuo, Yun-Feng Xiao, and Seok-Hyun Yun

Microlaser particles have emerged as unique optical probes for single-cell tracking. However, due to inherent directionality of laser emissions, cell tracking with laser particles suffers from frequent loss of cell traces. Recently, scientists at Harvard Medical School and Peking University placed omnidirectional visible laser particles into live cells, and demonstrated continuous spatial tracking of single cells. The technique will open new avenues for large-scale single-cell analysis in the study of cellular heterogeneity.


Laser particles are micrometer and nanometre lasers in the form of particles dispersible in aqueous solution, which have attracted considerable interest in the life sciences as a promising new optical probe. Laser particles emit bright light with extremely narrow spectral bandwidth. By transferring laser particles into live cells as shown in Figure 1, individual cells in a heterogeneous population can be tracked using each intracellular particle’s specific spectral fingerprint as an optically readable barcode. However, laser particles emit directional light (Figure 2) and freely disperse inside living cells, their orientation varying randomly over time. Therefore optical readout of these labels results in ‘lighthouse-like’ blinking, leading to frequent loss of cell traces.

In a new paper published in Light: Science & Applications, scientists from Professor Seok-Hyun Yun’s group at Harvard Medical School, and Professor Yun-Feng Xiao’s group at Peking University demonstrate single-cell tracking with intracellular laser particles engineered to emit nearly homogeneously in all directions. Omnidirectional laser emission is achieved by incorporating light scattering into the microdisk cavity, which reduces orientation dependent intensity fluctuations by two orders of magnitude (Figure 2), enabling blinking-free tracking of single cells under the same conditions where existing technology suffers from frequent tracking failure. The reported technique will open new avenues for large-scale single-cell analysis, and facilitate other applications of laser particles, such as cellular and biochemical sensing and single-cell analysis in microfluidics.

Tracking cells with omnidirectional visible laser particles
Schematic of the pumping and collection geometry (left). Laser intensity as a function of disk orientation. CLP: conventional microdisk LP; OLP: microdisk LP with omnidirectional emission by incorporating light scattering into the cavity. Credit: Shui-Jing Tang, Paul H. Dannenberg, Andreas C. Liapis, Nicola Martino, Yue Zhuo, Yun-Feng Xiao, and Seok-Hyun Yun

These scientists summarize the single-cell tagging principle of laser particles: “Typically, researchers use fluorescent probes to label specific cells, but only a few colors can be used at the same time before spectral overlap becomes a problem. Laser particles are tiny lasers that can be inserted inside living cells. These tiny lasers can be designed to produce many more distinguishable colors. The intracellular laser particles with a specific color will move with live cells, and therefore single cells can be tracked as they move throughout complex biological samples,” said Dr. Shui-Jing Tang, a former visiting student at Harvard Medical School and a current Boya postdoctoral researcher at Peking University.

“Unfortunately, laser particles emit light in a specific direction. When particles rotate freely over time as the cell moves, their apparent brightness, as seen by a photodetector, changes dramatically. We developed a new kind of laser particle emitting light in all directions. Therefore, the spatial cell traces could be tracked continuously no matter how each particle was oriented inside a cell,” added Paul Dannenberg, a graduate student at Harvard Medical School.

Tracking cells with omnidirectional visible laser particles
Lasing intensity traces as a function of time for three tracked CLPs (a) and OLPs (b) internalized by cells. CLP: conventional laser particles (CLP); OLP: omnidirectional laser particles. Credit: Shui-Jing Tang, Paul H. Dannenberg, Andreas C. Liapis, Nicola Martino, Yue Zhuo, Yun-Feng Xiao, and Seok-Hyun Yun

“The presented technique makes it possible to detect and identify laser particles reliably over time in cell tracking applications, which could enable large-scale single-cell analysis in complex biological specimens. In addition to cell-tracking, our work will facilitate other applications of laser particles, such as cellular and biochemical sensing and single-cell analysis in microfluidics,” said Dr. Andreas Liapis, a research fellow at Harvard University.


Wavelength-encoded laser particles for massively multiplexed cell tagging


More information:
Shui-Jing Tang et al, Laser particles with omnidirectional emission for cell tracking, Light: Science & Applications (2021). DOI: 10.1038/s41377-021-00466-0

Citation:
Tracking cells with omnidirectional visible laser particles (2021, February 2)
retrieved 4 February 2021
from https://phys.org/news/2021-02-tracking-cells-omnidirectional-visible-laser.html

This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no
part may be reproduced without the written permission. The content is provided for information purposes only.


Speak Your Mind

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Get in Touch

350FansLike
100FollowersFollow
281FollowersFollow
150FollowersFollow

Recommend for You

Oh hi there 👋
It’s nice to meet you.

Subscribe and receive our weekly newsletter packed with awesome articles that really matters to you!

We don’t spam! Read our privacy policy for more info.

You might also like