OCT-based technique captures subtle details of photoreceptor function

Researchers have developed a unique synchronized high-speed OCT/scanning light ophthalmoscope (SLO) system that captures the function of the retina’s rods and cones. The OCT images are co-registered with SLO images to pinpoint the location and type of photoreceptors captured in the series of 3D OCT images. The optical setup is shown. Credit: Mehdi Azimipour, UC Davis Eye Center.

Researchers have developed a new instrument that has, for the first time, measured tiny light-evoked deformations in individual rods and cones in a living human eye. The new approach could one day improve detection of retinal diseases such as age-related macular degeneration, a leading cause of blindness in people over 55 worldwide.


“Our instrument offers a unique way to study retinal disease at the cellular level,” said research team leader Ravi Jonnal from the University of California Davis (UC Davis) Eye Center. “Because existing methods for measuring dysfunction are much less sensitive, it offers a potential new way to detect disease.”

In The Optical Society (OSA) journal Optics Letters, Jonnal and colleagues describe their new instrument, which is based on optical coherence tomography (OCT). Using the new approach, they were able to measure how individual rods and cones respond to light, and could detect deformations that were significantly smaller than the wavelength of the imaging light source.

The work is part of an emerging international field of research that aims to develop methods to fully capture the function of the retinal neural circuit of living people.

Combining imaging methods

Vision begins when rod and cone photoreceptors in the eye’s retina detect light and initiate signals through a process called phototransduction. Retinal diseases such as age-related macular degeneration and retinitis pigmentosa cause vision loss by interfering with the function of rods and cones.

OCT-based technique captures subtle details of photoreceptor function
The simultaneously acquired OCT and scanning light ophthalmoscope (SLO) images. Rods are not as well resolved in the OCT projection (A) but can be identified in the SLO image (B). Scale bar is 10 micrometers. Credit: Mehdi Azimipour, UC Davis Eye Center.

Because rods are thought to be more sensitive to the impacts of these diseases, changes in their function could provide an early indicator of disease or its progression. However, the small size of rods makes it difficult to image them, much less measure how well they are functioning.

In the new work, the researchers developed a unique high-speed OCT system capable of detecting slight swelling in the outer segments of the photoreceptors that occurs as a side effect of phototransduction. The system accomplishes this by capturing specialized OCT images simultaneously with scanning light ophthalmoscope images, enabling it to pinpoint the location and type of photoreceptors captured in a series of hundreds of 3-D OCT images.

“Although imaging the swelling of rods and cones can reveal the dynamics of their response to light, until recently, it was not known if these changes could be measured in vivo in the human eye,” said Mehdi Azimipour, first author of the paper. “This is because the size of the photoreceptors and the scale of the light-evoked deformations were well below the resolutions provided by retinal imaging systems.”

Imaging high-speed dynamics

Recently, full-field OCT has been used to visualize the light-evoked deformation of larger peripheral cones. The OCT system developed by the researchers from UC Davis offers better confocality, which improves image quality by rejecting more scattered light and suppressing associated noise. Because the light-evoked deformation of photoreceptors can be very fast, the new system incorporates a high-speed Fourier-domain mode-locked laser that enables fast imaging and can scan 16 times faster than commercially available lasers used for swept source OCT.

OCT-based technique captures subtle details of photoreceptor function
(A) and (B) show the OCT images for two different stimulus light intensities. (C) and (D) show plots of the corresponding functional signals of select rods and cones in the field to the visible stimuli. No cone elongation is visible in response to the dimmer flash in (C), whereas a clear rod response is visible. In response to the brighter flash in (D), both rods and cones elongate, with the elongation of rods having several times higher amplitude. Credit: Mehdi Azimipour, UC Davis Eye Center.

To capture the highest resolution images possible, the researchers incorporated adaptive optics technology that measure the eye’s aberrations and corrects them in real time. Even with adaptive optics, rod photoreceptors are too small to be imaged due to the system’s 1-micron-wavelength light source. To overcome this problem, the researchers added a scanning light ophthalmoscope imaging channel that uses a wavelength that is less than 1 micron to increase the imaging resolution. This allowed differentiation of rods and cones in co-registered OCT images.

The researchers used their new instrument to measure the deformations of rods and cones in response to light of varying intensity in living human eyes. The responses of the cells increased as the light intensity increased until saturation occurred, consistent with phototransduction.

Because the new instrument produces large quantities of data (3.2GB/s) over even a small field of view, software needs to be developed to allow scanning of larger areas of retina and automatic data processing. This would make the system more practical for clinical use.

The researchers are now planning to use the instrument to measure photoreceptor light responses of patients with retinal diseases to see if new insights can be gained. “We hope to be involved in using the system to test novel therapies for blinding diseases, to speed up the process of bringing those therapeutics to the clinic,” said Azimipour.


Researchers uncover a critical early step of the visual process


More information:
Mehdi Azimipour et al, Optoretinogram: optical measurement of human cone and rod photoreceptor responses to light, Optics Letters (2020). DOI: 10.1364/OL.398868

Citation:
OCT-based technique captures subtle details of photoreceptor function (2020, August 19)
retrieved 19 August 2020
from https://phys.org/news/2020-08-oct-based-technique-captures-subtle-photoreceptor.html

This document is subject to copyright. Apart from any fair dealing for the purpose of private study or research, no
part may be reproduced without the written permission. The content is provided for information purposes only.


Speak Your Mind

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Get in Touch

350FansLike
100FollowersFollow
281FollowersFollow
150FollowersFollow

Recommend for You

Oh hi there 👋
It’s nice to meet you.

Subscribe and receive our weekly newsletter packed with awesome articles that really matters to you!

We don’t spam! Read our privacy policy for more info.

You might also like